E

EMC

EN 55032 / CISPR 32 Class A RE Limits

Radiated Emissions Requirements for Class A Equipment

This table details the Radiated Emission (RE) limit requirements for Class A equipment according to EN 55032 / CISPR 32, covering measurements up to 1 GHz and above 1 GHz for OATS/SAC, FAR, and FSOATS facilities. Essential reference for commercial and industrial EMC compliance.

Class A Equipment Limits
Levels in dB(µV/m). Scroll horizontally to view more.
Clause Frequency (MHz) Facility Distance (m) Detector / Bandwidth Limits
Up to 1 GHz
A2.1 30 to 230 OATS/SAC 10 Quasi Peak / 120 kHz 40
230 to 1 000 OATS/SAC 10 Quasi Peak / 120 kHz 47
A2.2 30 to 230 OATS/SAC 3 Quasi Peak / 120 kHz 50
230 to 1 000 OATS/SAC 3 Quasi Peak / 120 kHz 57
A2.3 30 to 230 FAR 10 Quasi Peak / 120 kHz 42 to 35
230 to 1 000 FAR 10 Quasi Peak / 120 kHz 42
A2.4 30 to 230 FAR 3 Quasi Peak / 120 kHz 52 to 45
230 to 1 000 FAR 3 Quasi Peak / 120 kHz 52
Above 1 GHz
A3.1 1 000 to 3 000 FSOATS 3 Average / 1 MHz 56
3 000 to 6 000 FSOATS 3 Average / 1 MHz 60
A3.2 1 000 to 3 000 FSOATS 3 Peak / 1 MHz 76
3 000 to 6 000 FSOATS 3 Peak / 1 MHz 80